| | 3200BEP Strobe Explosion-Proof Strobe
 | The 3200BEP family of single flash explosion-proof UL listed strobe lights is designed for operation in hazardous areas rated Class I Group C & D (gas hazards) and Class II Group E, F, & G (dust hazards). Division 2 locations are defined by the NFPA as described at the bottom of this page. Design features include a housing made of die cast high strength copper-free aluminum alloy with a baked powder epoxy finish, stainless steel hardware, o-ring sealed prestressed glass globe with double pitch acme threads for smooth assembly and ease of maintenance, and an optional guard which need not be removed for relamping. 3/4” conduit hubs are standard. |
$893.27 | Features |  |
- Single flash
- Xenon strobe lamp
- Available in amber, blue, clear, green, and red
- 2 year warranty on power supply
- 1 year warranty on lamp
- UL listed (where noted below)
|
| 3000 Models |  |
 | |  | |  | | Pendant Mount | | Flange Mount | | Wall Mount |
| Model | Description | Voltage | | 3150BEP–PM | 3/4” pendant mount | 12 – 74VDC | | 3200BEP–PM | 3/4” pendant mount | 120VAC | | 3300BEP–PM | 3/4” pendant mount | 240VAC | | 3150BEP–FM | 3/4” flange mount | 12 – 74VDC | | 3200BEP–FM | 3/4” flange mount | 120VAC | | 3300BEP–FM | 3/4” flange mount | 240VAC | | 3150BEP–WM | 3/4” wall mount | 12 – 74VDC | | 3200BEP–WM | 3/4” wall mount | 120VAC | | 3300BEP–WM | 3/4” wall mount | 240VAC |
| Specifications |  |
| Item | Description | | Lamp Type | 700–R1–COLOR ( please specify lens color ) | | Voltage and Amperage | 12–74VDC draws 1.25A @ 12VDC tampering to 0.2A @ 74VDC 120/240VAC draws 0.17A @ 120VAC (50/60Hz) draws 0.075A @ 240VAC | | Temperature Code | T6–Class I Groups C and D T4A–Class II Groups E, F, & G | | Temperature Range | –40° C to +55° C | | Power Supply Output | 13 watts standard, 11 watts for model 3150 9 joules per flash standard, 8 joules per flash for model 3150 | | Flash Rate | 85 flashes per minute | | Size and Weight | 13.69” tall x 7.44” dia. x 10.6 lbs ( 347mm x 188mm x 4.7kg ) |
| NFPA Definitions |  |
Class I, Division 2. A location (1) in which volatile flammable liquids or flammable gases are handled, processed or used, but in which the liquids, vapors or gases will normally be confined within closed containers or closed systems from which they can escape only in case of accidental rupture or breakdown of such containers or systems, or in case of abnormal operation of equipment; or (2) in which ignitable concentrations of gases or vapors are normally prevented by positive mechanical ventilation, and which might become hazardous through failure or abnormal operation of the ventilating equipment; or (3) that is adjacent to a Class I Division 1 location, and to which ignitable concentrations of gases or vapors might occasionally be communicated unless such communication is prevented by adequate positive–pressure ventilation from a source of clean air and effective safeguards against ventilation failure are provided. [See Section 500–4(b) of NFPA 70, National Electrical Code.] |
Class II, Division 2. A location in which (1) combustible dust will not normally be in suspension in the air in quantities sufficient to produce explosive or ignitable mixtures and dust accumulations are normally insufficient to interfere with the normal operation of electrical equipment or other apparatus; or (2) dust may be in suspension in the air as a result of infrequent malfunctioning of handling or processing equipment and dust accumulations resulting there from may be ignitable by abnormal operation or failure of electrical equipment or other apparatus. [See Section 500–5 (b) of NFPA 70, National Electrical Code.] |
|
|
|
|
|
|
|